Concrete Admixtures Construction Concrete Admixture

The performance and characteristics of fibre-reinforced concrete need to be tested with methods tailored to suit the specific end application, to make sure it can be used safely in future specifications. These test methods are now fully-standardised internationally through the European Standards (EN), as well as the American Society for Testing and Materials (ASTM).

The performance and characteristics of fibre-reinforced concrete need to be tested with methods tailored to suit the specific end application, to make sure it can be used safely in future specifications. These test methods are now fully-standardised internationally through the European Standards (EN), as well as the American Society for Testing and Materials (ASTM).

Fibre-Reinforced Concrete and Mortar – Standards and Testing

Test method Standard Description
Energy absorption ASTM C1550 Round panel test
  EN 14488-5 Square panel test
Residual strength EN 14651 Beam test
Fire resistance RWS Max. 1,350°C, 2 hours
  ISO 834 Starts at low temp, but continuously increasing
  HC modified Max. 1,200°C, 4 hours
Shrinkage cracking ASTM C 1581-04 Test method for determining restrained shrinkage
Impact resistance Various local standards Impact energy tests
Concrete Standards and Test
Image: Round panel test: ASTM C1550
Concrete Standards and Test
Image: Square Panel test: EN 14488-5
Concrete Standards and Test
Image: Beam test: EN 14651