Sikaplan® G-15
Polymeric PVC membrane for mechanically fastened roof waterproofing
Sikaplan® G-15 (thickness 1.5 mm) is a polyester reinforced, multi-layer, synthetic roof waterproofing sheet based on polyvinyl chloride (PVC) containing ultraviolet light stabilisers and flame retardant according to EN 13956. It is hot air weldable and formulated for direct exposure and designed for use in all global climatic conditions.
- Resistant to UV exposure
- Resistant to permanent wind exposure
- Resistant to most common environmental influences
- Hot air weldable
- No open flame equipment required
- High water vapour permeability
Usage
Waterproofing membrane for:- Mechanically fastened roofing systems
Advantages
- Resistant to UV exposure
- Resistant to permanent wind exposure
- Resistant to most common environmental influences
- Hot air weldable
- No open flame equipment required
- High water vapour permeability
Packaging
Roll length | 20.00 m | 20.00 m | 20.00 m | 20.00 m |
Roll width | 0.77 m | 1.00 m | 1.54 m | 2.00 m |
Roll weight | 27.72 kg | 36.00 kg | 55.44 kg | 72.00 kg |
Refer to price list for packaging variations.
Colour
Surface: | Matt |
Colours | |
Top surface: | Light grey (~RAL 7047) |
Bottom surface: | Dark grey |
Top surface of sheet in other colours available on request, subject to minimum order quantities.
Product Details
ENVIRONMENTAL INFORMATION
- Conformity with LEED v4 SSc 5 (Option 1): Heat Island Reduction - Roof (only traffic white)
- Conformity with LEED v4 MRc 2 (Option 1): Building Product Disclosure and Optimization – Environmental Product Declarations
- Conformity with LEED v4 MRc 3 (Option 2): Building Product Disclosure and Optimization - Sourcing of Raw Materials
- IBU Environmental Product Declaration (EPD) available
APPROVALS / STANDARDS
- BBA Agrement Certification (09/4668)
- EN13501-5 Broof(t4) (as part of system)
- Polymeric sheets for roof waterproofing according to EN 13956, certified by notified body 1213-CPD-4125/4127 and provided with the CE-mark
- Reaction to fire according to EN 13501-1. Class E (membrane alone)
- Factory Mutual (FM) Approval Class: 4470
- Quality Management system in accordance with EN ISO 9001/14001
Product Declaration
EN 13956 - Polymeric sheets for roof waterproofing
Chemical Base
Polyvinyl chloride (PVC)
Shelf Life
5 years from date of production.
Storage Conditions
Product must be stored in original unopened and undamaged packaging in dry conditions and temperatures between + 5 °C and + 30 °C. Store in a horizontal position. Do not stack pallets of the rolls on top of each other, or under pallets of any other materials during transport or storage. Always refer to packaging.
Visible Defects
Pass | (EN 1850-2) |
Length
20 m (-0 % / +5 %) | (EN 1848-2) |
Width
0.77 m / 1.00 m / 1.54 m / 2.00 m (-0.5 % / +1 %) | (EN 1848-2) |
Effective Thickness
1.5 mm (-5 % / +10 %) | (EN 1849-2) |
Straightness
≤ 30 mm | (EN 1848-2) |
Flatness
≤ 10 mm | (EN 1848-2) |
Mass per unit area
1.8 kg/m² (-5 % / +10 %) | (EN 1849-2) |
System Structure
The following products must be considered for use depending on roof design:
▪ Sikaplan®-18 D, un-reinforced sheet for detailing
▪ Moulded corner pieces, prefabricated corners and pipe flashings
▪ Sika® Trocal® Metal Sheet Type S
▪ Sika® Trocal Cleaner-2000
▪ Sika® Trocal Cleaner L-100
▪ Sika® Trocal C-733 (Contact adhesive)
Wide range of accessories is available e.g. prefabricated parts, roof drains, scuppers, walkway pads and decor profiles.
Compatibility
Not compatible with direct contact to other plastics e.g. EPS, XPS or PF – note Sikaplan G is compatible with PIR that has Glass tissue or foil facing, but not compatible with unfaced PIR material and should not be in direct contact. Not resistant to tar, bitumen, oil and solvent containing materials. These materials could adversely affect the product properties.
Resistance to Impact
hard substrate | ≥ 400 mm |
soft substrate | ≥ 700 mm |
Hail Resistance
rigid substrate: | ≥ 21 m/s |
flexible substrate: | ≥ 26 m/s |
Tensile Strength
longitudinal (md)1) | ≥ 1000 N/50 mm |
transversal (cmd)2) | ≥ 900 N/50 mm |
Elongation
longitudinal (md)1) | ≥ 15 % |
transversal (cmd)2) | ≥ 15 % |
Tear Strength
longitudinal (md)1) | ≥ 150 N |
transversal (cmd)2) | ≥ 150 N |
Joint Peel Resistance
Failure mode: C, no failure of the joint | (EN 12316-2) |
Joint Shear Resistance
≥ 600 N/50 mm | (EN 12317-2) |
Dimensional Stability
longitudinal (md)1) | ≤ |0.5| % |
transversal (cmd)2) | ≤ |0.5| % |
Solar Reflectance
Colour | Initial | 3 years aged | Test institute |
traffic white RAL 9016 | 0.86 | 0.67 | CRRC |
Solar Reflectance Index
Colour | Initial | 3 years aged | Test institute |
traffic white RAL 9016 | 109 | 81 | CRRC |
CRRC tested products are listed in Cool Roof Rating Council (CRRC) product data base.
Thermal Emittance
Colour | Initial | 3 years aged | Test institute |
traffic white RAL 9016 | 0.90 | 0.87 | CRRC |
Foldability at Low Temperature
≤ -25 °C | (EN 495-5) |
Water Tightness
Pass | (EN 1928) |
Effect of Liquid Chemicals, Including Water
On request | (EN 1847) |
UV Exposure
Pass (> 5000 h / grade 0) | (EN 1297) |
External Fire Performance
BROOF(t4) ≤ 10° (as part of roof system) | (EN 13501-5) |
Reaction to Fire
Class E | (EN ISO 11925-2, classification to EN 13501-1) |
Application
Ambient Air Temperature
-15 °C min. / +60 °C max.
Substrate Temperature
-25 °C min. / +60 °C max.
EQUIPMENT
Hot welding overlap seams
Electric hot air welding equipment, such as hand held manual hot air welding equipment and pressure rollers or automatic hot air welding machines with controlled hot air temperature capability of a minimum +600 °C.
Recommended type of equipment:
Manual: Leister Triac
Automatic: Leister Varimat or similar
Semi-automatic: Leister Triac Drive
SUBSTRATE QUALITY
The substrate surface must be uniform, smooth and free of any sharp protrusions or burrs, etc. Sikaplan® G-15 must be separated from any incompatible substrates / materials by an effective separation layer to prevent accelerated ageing. The supporting layer must be compatible to the membrane, solvent resistant, clean, dry and free of grease and dust. Metal sheets must be degreased with Sika® Trocal Cleaner-2000 before adhesive is applied.
APPLICATION
Installation procedure
Reference must be made to further documentation where applicable, such as relevant method statement, application manual and installation or working instructions.
Fixing method – General
The waterproofing membrane is installed by loose laying (without stretching membrane or installing under tension) with mechanical fastening in seam overlaps or independent from overlaps. Overlap seams are hot welded using specialised hot air equipment.
Fixing method-Spot fastening
Sikaplan® G-15 must always be installed at right angles to the deck direction. Sikaplan® G-15 is fixed by fasteners and washers/tubes along the marked line, 10 mm from the edge of the membrane. Sikaplan® G-15 is overlapped by 120 mm. The spacing of the fasteners is in accordance with the project specific Sika calculations. At upstands and at all penetrations, the membrane must be secured by additional fasteners and washers/tubes. The fasteners and washers/tubes protect the Sikaplan® G-15 roof covering against tearing and peeling off by wind uplift.
Hot welding method
Overlap seams must be welded by electric hot welding equipment. Welding parameters including temperature, machine speed, air flow, pressure and machine settings must be evaluated, adapted and checked on site according to the type of equipment and the climatic conditions prior to welding.
Testing overlap seams
The seams must be mechanically tested with a screw driver (rounded edges) to ensure the integrity/completion of the weld. Any imperfections must be rectified by hot air welding.