Sika® Injection Cleaner C1
Sika® Injection Cleaner C1 is a 1-part cleaning agent for cleaning injection pumps during or directly after injection. It removes liquid epoxy and polyurethane resins.
- Cleaning agent for intermediate and final cleaning
- Cleaning agent for polyurethane and epoxy resins
- Free of CFC’s, FC and chlorine
Usage
- Cleaning agent for injection pumps
Advantages
- Cleaning agent for intermediate and final cleaning
- Cleaning agent for polyurethane and epoxy resins
- Free of CFC’s, FC and chlorine
Packaging
Refer to current price list for packaging variations.
Colour
Colourless
Product Details
Shelf Life
24 months from date of production
Storage Conditions
The product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +30 °C. Always refer to packaging.
Compatibility
Polyurethane Resins/Foams/Epoxy Resins
Intermediate Cleaning | Sika® Injection Cleaner C1 |
Final Cleaning | Sika® Injection Cleaner C1 |
Removal of cured material | Sika® Injection Cleaner C2 |
Preservation of pumps | Sika® Injection Conservator |
Silicate Resins
Intermediate Cleaning | Comp. A: Water Comp. B: Sika® Injection Cleaner C1 |
Final Cleaning | Sika® Injection Cleaner C1 |
Removal of cured material | Sika® Injection Cleaner C2 |
Preservation of pumps | Sika® Injection Conservator |
Acrylate Resins
Intermediate Cleaning | Water |
Final Cleaning | Water + standard dishwashing liquid |
Removal of cured material | Sika® Injection Cleaner C2 |
Preservation of pumps | Sika® Injection Conservator |
Application
APPLICATION
Intermediate cleaning
From the container, remove an adequate quantity of the cleaning agent (depends on pump size) and pump through the injection pump until the out-flow of the cleaning agent shows no discoloration or transports no visible injection resin residue.
Note: The cleaning of an injection pump during the working day can often be necessary because of breaks or interruptions to the work or when fast-reacting injection resins are used. In such a case, clean the pump as a preventive measure to avoid resin build-up and blocking of the pump. Intermediate pump cleaning is also needed if the injection material type is changed. Always take care to ensure the selected cleaning agent is suitable for both types of injection material. Otherwise it will be necessary to clean the pump first with a suitable cleaning agent for the injection material that has just been used and then to clean the pump again with a suitable cleaning agent for the new injection material.
Final cleaning
From the container, remove an adequate quantity of the cleaning agent (depends on pump size) and pump through the injection pump until the out-flow of the cleaning agent shows no discoloration or transports no visible injection resin residue. Cycle the cleaner for at least 2 minutes through the pump. Cleaning agent may stay inside the pump. If the pump is not to be used for a long time, it is recommended to replace the remaining cleaning agent by flushing with Sika Injection Conservator.
Note: The final cleaning after every working day is required. If the injection pump is not properly cleaned there is a risk of a resin build-up and blocking of the pump.
Disposal
Used cleaning and preservative agents must be collected in suitable sealable containers and must be disposed of in accordance with relevant local regulations.