Sikafloor® MultiDur ES-39
Sikafloor® MultiDur ES-39 is a smooth, tough-elastic, coloured epoxy covering with improved chemical resistance for flooring applications
- Improved chemical resistance
- Crack-bridging
- Liquid proof
Usage
Crack-bridging and chemically resistant coating for concrete and screed surfaces in bund areas for the protection against water contaminating liquidsAdvantages
- Improved chemical resistance
- Crack-bridging
- Liquid proof
Packaging
Please refer to the individual Product Data Sheet
Colour
Available in various colour shades.
Appearance
Smooth, gloss finish
System Details
APPROVALS / STANDARDS
- Fire classification in accordance with DIN EN 13501-1: 2010, class Bfl-S1, Report-No. KB-Hoch-141525, Germany, January, 2015
- Approval as “Water protection system”, Z-59.12-392, DIBt, Germany
- Static crack-bridging test, class A5 according to EN-1262-7, Report No.PB 5.1/12-099-1, MFPA Leipzig GmbH, Germany, September 2012
System Structure
Sikafloor® MultiDur ES-39
Layer | Product |
1. Primer | Sikafloor®-156/-161 |
2. Wearing coat | Sikafloor®-390 N |
Composition
Epoxy
Nominal Thickness
~2.0–3.0 mm
Shelf Life
Please refer to the individual Product Data Sheet
Storage Conditions
Please refer to the individual Product Data Sheet
Shore D Hardness
~60 (7 days at 23°C ) | ZG (German Standard for water protection) |
Crack Bridging Ability
0.4 mm Static, class A5 (23 °C) | (DIN EN 1062-7) |
Reaction to Fire
Bfl-S1 | (DIN EN 13501-1) |
Chemical Resistance
Please refer to the chemical resistance of Sikafloor®-390 N
Thermal Resistance
Exposure* | Dry heat |
Permanent | +50 °C |
Short-term max. 7 d | +80 °C |
Short-term max. 12 h | +100 °C |
Short-term moist/wet heat* up to +80 °C where exposure is only occasional (i.e. during steam cleaning etc.)
*No simultaneous chemical and mechanical exposure.
Application
Product Temperature
Please refer to the individual Product Data Sheet
Ambient Air Temperature
+10 °C min. / +30 °C max.
Relative Air Humidity
80 % r.h. max.
Dew Point
Beware of condensation!
The substrate and uncured floor must be at least 3 °C above dew point to reduce the risk of condensation or blooming on the floor finish.
Substrate Temperature
+10 °C min. / +30 °C max.
Substrate Moisture Content
When performing application work with Sikafloor® MultiDur ES-39, the substrate moisture content must not exceed 4 % pbw measured by Tramex.
Test method: Sika®-Tramex meter, CM - measurement or Oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Waiting Time / Overcoating
Before applying Sikafloor®-390 N on Sikafloor®-156/161/160 allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 24 hours | 4 days |
+20 °C | 12 hours | 2 days |
+30 °C | 8 hours | 1 day |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Applied Product Ready for Use
Temperature | Foot traffic | Light traffic | Full cure | |
+10 °C | ~48 hours | ~6 days | ~10 days | |
+20 °C | ~30 hours |
| ~7 days | |
+30 °C | ~20 hours | ~3 days | ~5 days |
For traffic with solid / hard wheeled lift trucks allow 3 weeks curing time.
Consumption
Sikafloor® MultiDur ES-39 system (~2–3 mm)
Coating System | Product | Consumption |
Primer | 1 × Sikafloor®-156/-161 | ~0.3–0.5 kg/m² |
Wearing coat | Sikafloor®-390 N (unfilled) | ~1.6 kg/m²/mm |
CLEANING
Please refer to the Sikafloor®‐ Cleaning Regime