WARNING
Hazardous respirable droplets may be formed when sprayed.
- Do not breathe spray or mist.
IMPORTANT
Reduced service life due to incorrect treatment of cracks
The incorrect assessment and treatment of cracks may lead to a reduced service life and reflective cracking.
- For static cracks, ensure the width is suitable for overcoating with Sikagard®-403 W.
- For dynamic cracks, ensure the movement is within the movement capacity of Sikagard®-403 W.
IMPORTANT
Risk of crazing due to excess moisture
Crazing may occur if coating undried surfaces.
- Ensure the entire surface is fully dry before proceeding.
- Allow new concrete substrates to cure or hydrate for a minimum of 10 days, and preferably 28 days.
IMPORTANT
Application on acoustic boards
Acoustic boards may lose some acoustic absorption after coating.
IMPORTANT
Ventilation in confined spaces
Always ensure good ventilation when applying the Product in a confined space.
IMPORTANT
Temporary heating
If temporary heating is required, do not use gas, oil, paraffin or other fossil fuel heaters, these produce large quantities of both CO2 and H2O water vapour, which may adversely affect the finish. For heating use only electric powered warm air blower systems.
Surface profile due to reinforcement
Note: A slightly rough surface profile will be visible if the Product is reinforced with Sika® Reemat Premium.
ROLLER APPLICATION
- IMPORTANT For aesthetic reasons, use the same roller type in the same areas. Apply the Product to the correct film thickness per layer with a short-pile roller.
AIRLESS SPRAY APPLICATION
This method leads to a smoother surface compared to roller application.
- IMPORTANT Use the same application type in the same areas. Apply the Product to the correct film thickness per layer with airless spraying application equipment, use tip sizes from 0.38–0.53 mm and a fan angle from 40° to 60°.